Euro Physical Acoustics, the Non Destructive Testing Solution

English Version

Versión Española

Rechercher

  

 

   
    Home > Services > Tubing Inspection  ,...

 

    IRIS

    Ultrasonics

    Eddy Current

    Remote Field Testing
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 





The best adapted methods  for tubing inspection
of boilers, heat exchangers, air coolers, feed waters heaters, condensers, ...

 

 " IRIS " ULTRASONIC tubing inspection


An
immersion pulse-echo technique is used. The ultrasonic transducer is housed in a turbine head with a rotating 45° mirror. The turbine assembly is centred in the tube axis. These pulses are emitted parallel to the tube axis and are reflected by the 45° mirror so that they are directed radially into the tube wall. The reflections from both inner and outer tube wall follow the same path to the transducer. The time interval between the first wall echo (front) and second wall echo (back) is the measure of wall thickness. As the mirror rotates, the ultrasonic beam sweeps the entire circumference of the tube wall.

                                                                                                                             Principle of IRIS System

 Ultrasonic IRIS system Advantages :

Exchanger tubing instection with the  Ultrasonics Ultima IRIS System Ferrous and non ferrous materials
Tube range from 10 mm internal diameter
Tubes ferreux et non ferreux
Uses rotating pulse-echo technique to scan 100% of tube wall area
Data presented in B and interactive C scan displays with tube sheet
   mapping software
Data files are color thickness coded and interactive
Data saving
 


 Ultrasonic Ultima IRIS System Applications
 :

 Used for boiler tubes, heat exchangers, air coolers, feed water heaters, condensers

 
Finding of flaws [OD or ID]: corrosion, erosion, wall thinning,…

 
Following of flaws evolution during the life of the tube

  ULTRASONIC TUBING INSPECTION SYSTEM " TUBESCAN "

Ultrasonics Tubing inspection system!:  TUBESCANTUBESCAN® is an ultrasonic internal tubing inspection with mirror, fully automatic and designed to quickly obtain a C-SCAN mapping of small to middle diameter tubes.  It can be used for  boiler, heat exchanger, condensers.... tubes.

For more information bout TUBESCAN® system , click here.
 

MULTIFREQUECY EDDY CURRENT TUBING inspection

Heat exchanger tubing exam with eddy current is performed with an Eddy Current axial probeinternal bobbin. The principle is to study the impedance variation of the coils inside a non-ferromagnetic tube. The injection of multiple frequencies allows by using a mixing to eliminate unwanted signal from structure, and so to detect and evaluate the degradation under the support.
                                                                                                                            
Eddy Current axial probe
 

 Multifrequency  Eddy Current method Advantages:

   Flexible or heady-duty axial probe
 
 
Rotating Pancake Coil,
 
 
Analysis software with location of the defect along the tube
 
 
Final report with mapping of inspection
 
 
Data saving
   Calibration standard with metrology certificate
 

 Multifrequency  Eddy Current Applications:

  Periodic tubing exam for heat exchanger, fin-fan cooling buddle
 
Flaw research [OD or ID]: cracks, corrosion, erosion, wall thinning,…
 Following of flaw evolution during the life of the tube

  REMOTE FIELD EDDY CURRENT TUBING INSPECTION

The Remote Field Testing [RFT] is using for ferromagnetic (carbon steel) tubing inspection. The specific probe use coils for the exciter and for the receiver far to 2xOD of the tube. The principle is based on the magnetic field variation study of the coils from the exciter to the receiver along the tube. The display in absolute and differential mode allows to find slow and pitting defect, like erosion and corrosion.
                                                                                                                       Remote Field Eddy Current  probe

 Remote Field  Eddy Current Advantages:

   Straight or U-bend tubing inspection, ID from 10 to 100mm
 
 
Limit of detection : 20% of wall thinning
 
 
Flexible or heady-duty axial probe
 
 
Analysis software with location of the defect along the tub
   Final report with mapping of inspection
 
 
Data saving
   Calibration standard with metrology certificate
   No necessity of HP cleaning
   High rate of control
   Possibility to associate IRIS method to quantify the wall thinning

Remote Field  Eddy Current Applications  :
 
Exchanger tubing inspection with Remote Field Testing methodamps Lointains
Periodic tubing exam for heat exchanger, boiler, reactor,...
Flaw research [OD or ID]: cracks, corrosion, erosion, wall thinning,…
Preliminary Service Inspection in workshop on new buddle
Following of flaws evolution during the life of the tube

 

 

 

 PicoSearch