IRIS
Ultrasonics
Eddy
Current
Remote
Field
Testing
|
|

The best adapted methods for tubing inspection
of boilers, heat exchangers, air coolers, feed waters heaters, condensers,
...
|
ULTRASONIC TUBING INSPECTION SYSTEM
"
TUBESCAN "
TUBESCAN®
is an ultrasonic internal tubing inspection with mirror, fully automatic
and designed to quickly obtain a C-SCAN mapping of small to middle
diameter tubes. It can be used for boiler, heat exchanger,
condensers.... tubes.
For more information bout TUBESCAN®
system , click here.
|
|
 |
|
MULTIFREQUECY EDDY CURRENT TUBING
inspection
|
|
Heat exchanger tubing exam with eddy current is performed with an
internal
bobbin.
The
principle is to study the impedance variation of the coils inside a
non-ferromagnetic tube. The injection of multiple frequencies allows
by
using a mixing to eliminate unwanted signal from structure,
and so to
detect and evaluate the degradation under the support.
Eddy Current axial probe
|
|
Multifrequency Eddy
Current method Advantages:

Flexible
or heady-duty axial probe
Rotating
Pancake Coil,
Analysis
software with location of the defect along the tube
Final
report with mapping of inspection
Data
saving
Calibration
standard with metrology certificate
|
|
Multifrequency Eddy
Current Applications:
Periodic tubing exam for heat exchanger, fin-fan cooling buddle
Flaw
research
[OD or ID]: cracks, corrosion, erosion, wall thinning,…
Following
of flaw evolution during the life of the tube
|
|
|